• M-Bus Communication Power Quality Monitor Over Current Alarm AC Electrical Sensor
  • M-Bus Communication Power Quality Monitor Over Current Alarm AC Electrical Sensor
  • M-Bus Communication Power Quality Monitor Over Current Alarm AC Electrical Sensor
  • M-Bus Communication Power Quality Monitor Over Current Alarm AC Electrical Sensor

M-Bus Communication Power Quality Monitor Over Current Alarm AC Electrical Sensor

Application: Electronic, Instrument, Position Sensor, Lighting, Submetering System
Type: Current Transformer
Phase: Single
Operation Condition: Outdoor
Usage: Protection, Measurement, Monitoring
Winding Form: Small Fixed Type
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Basic Info.

Model NO.
D129072
Insulating Medium
Common Insulating Materials
Installation
Penetration Type
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Electromagnetic Type
Measurement
AC DC
Active
Class 1
Communication
M-Bus Communication
Temperature Accuracy
2 Degree Centigrade
Transport Package
Cartons
Specification
TBA
Trademark
IVY
Origin
Zhejiang, China
HS Code
9028301300
Production Capacity
5, 000, 000.00/ Year

Product Description

M-Bus Communication Power Quality Monitor Over Current Alarm AC Electrical SensorM-Bus Communication Power Quality Monitor Over Current Alarm AC Electrical Sensor
Specification Data Measuring Current Range 100A
Accuracy Class Class 1
Temperature Accuracy 2ºC
Frequency 50-60Hz
Wiring Diameter ≤φ12mm
Operation Temperature -20~+85ºC
Withstand Voltage >3000VAC
Response Time 200mS
Communication M-BUS Communication
M-Bus Communication Power Quality Monitor Over Current Alarm AC Electrical SensorM-Bus Communication Power Quality Monitor Over Current Alarm AC Electrical SensorM-Bus Communication Power Quality Monitor Over Current Alarm AC Electrical Sensor
Cautions of Smart Sensor:
1.Current value- Please specify your measurement range as per your application, for example if you are going to
use it for detecting and sensing mA level or high  current range such as 500A/600A shall be first factor.
2.AC,DC,or both AC&DC shall be the second factor. Now current sensor on the market usually are AC or DC type.
But if you need both AC& DC you may need to use IVY brand- AC DC leakage sensor.
3.Parameters-Please confirm what kind of parameters shall be measured or detected. For example our smart sensor
with shunt can readout current, voltage,kWh, kVar, Cos
φ, Hz, THF, current cycle, starting waveform.
4.Communication-RS485,M-bus, UART serial port are optional, if you have more requirements we can also develop for you.
5.Installation Method, after making above decision you may also need to confirm the output terminal type, for example we have
shunt / terminal / pillar / pins/ cable etc.
6.
As there are many models of smart electrical sensor, plz refer to the detailed specification and use it as per the instruction.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Registered Capital
1000000 RMB
Type of Ownership
Limited Company
Management System Certification
ISO 9001, ISO 14001, QC 080000