• UL 63A 80A 250VAC 12VDC Coil Single Pole Normally Open EV Power Contactor Relay
  • UL 63A 80A 250VAC 12VDC Coil Single Pole Normally Open EV Power Contactor Relay
  • UL 63A 80A 250VAC 12VDC Coil Single Pole Normally Open EV Power Contactor Relay
  • UL 63A 80A 250VAC 12VDC Coil Single Pole Normally Open EV Power Contactor Relay
  • UL 63A 80A 250VAC 12VDC Coil Single Pole Normally Open EV Power Contactor Relay
  • UL 63A 80A 250VAC 12VDC Coil Single Pole Normally Open EV Power Contactor Relay

UL 63A 80A 250VAC 12VDC Coil Single Pole Normally Open EV Power Contactor Relay

Theory: Electromagnetic Relay
Usage: Household Appliances Relay, Stabilizer, Industry, UPS, EV Charger
Phase: 1
Electricity Type: Ac
Number of Pole: 1
Load: High Power Relay
Samples:
US$ 0.00/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Basic Info.

Model NO.
IM-NE802
Protective Characteristics
Open Relay
Action Principle
Electromagnetic Type
Size
Miniature
Type
Electric Parameter Relay
Product Name
UL 63A Single Pole EV Power Contactor Relay
Part Number
Im-Ne802
Max Current
100A
Contact Arangement
1A
Contact Capacity
100A, 250VAC/28VDC
Coil Voltage
6~220VDC/6~220VAC
Contact Material
Agsno2
Weight
210.0g
Mounting Method
Screw Fasten
Transport Package
120PCS in 1 Carton
Specification
63.5*63.5*56mm
Trademark
wanjia star
Origin
Zhejiang, China
HS Code
8536411000
Production Capacity
5, 000, 000.00/ Year

Product Description

UL 63A 80A 250VAC 12VDC Coil Single Pole Normally Open EV Power Contactor RelayUL 63A 80A 250VAC 12VDC Coil Single Pole Normally Open EV Power Contactor RelayUL 63A 80A 250VAC 12VDC Coil Single Pole Normally Open EV Power Contactor RelayUL 63A 80A 250VAC 12VDC Coil Single Pole Normally Open EV Power Contactor RelayUL 63A 80A 250VAC 12VDC Coil Single Pole Normally Open EV Power Contactor Relay
                                                                               Main Parameter
Contact Type 1A
Contact Material Silver Alloy
Contact Resistance Max.50mΩ
Rated Load 100A 250VAC
100A 28VDC
Max. Switching Voltage 28VDC/250VAC
Max. Switching Current 30A/100A
Max. Switching Power 840W/7500VA
(2800W/25000VA)
Electrical Life 2×104
Mechanical Life 1×107
Coil Power Consumption DC 2.2W
AC 10VA
Coil Voltage DC 6~220VDC
AC 6~220VAC
 
                                                                                Other Parameters
Movement Time Max.30ms
Release Time Max.30ms
Starting Resistance Coil Contacts 2000VAC ,(50/60Hz), 1 min.
Open Contacts 1500VAC ,(50/60Hz), 1 min.
Insulation Resistance Min. 1000MΩ (500 VDC)
Environment Temperature -40ºC~+55ºC
Operation Humidity 45%~85% RH
Shock Resistance Functional Min. 10G
Destructive Min. 100G
Anti-vibration Functional 1.5mm(DA)10~55 Hz
Destructive 1.5mm(DA)10~55 Hz
Weight ≤210g
UL 63A 80A 250VAC 12VDC Coil Single Pole Normally Open EV Power Contactor RelayUL 63A 80A 250VAC 12VDC Coil Single Pole Normally Open EV Power Contactor RelayUL 63A 80A 250VAC 12VDC Coil Single Pole Normally Open EV Power Contactor RelayUL 63A 80A 250VAC 12VDC Coil Single Pole Normally Open EV Power Contactor RelayUL 63A 80A 250VAC 12VDC Coil Single Pole Normally Open EV Power Contactor RelayUL 63A 80A 250VAC 12VDC Coil Single Pole Normally Open EV Power Contactor Relay
Cautions of Power Relay:
 
1.Suggestions of Plastic Anti-dust Cover
We highly recommend cover :
(1)When the ambient humidity is ≥ 60% (for example refrigerator or some country like Indian), the metal parts of relay will be weakened in different degrees
due to long-term exposure to the outdoors in terms of electrical conductivity and service life.

(2)When the dust density is high in the environment, all kinds of impurities carried in the dust (such as gravel), if gravel is embedded between contacts.
Firstly, it will affect the normal opening and closing of contacts;Secondly, part of the silicon oxide can be used as a semiconductor to conduct electricity,
and then the relay's on and off will fail if no anti-dust cover.

(3)When corrosive gases are serious in the environment, it will accelerate the metal aging, greatly affecting the service life of electrical relays.
* When none of the above situations exists, the plastic anti-dust cover is not necessary due to extra cost.
2.Suggestions of Contacts
(1)We should pay attention to prevent contact movement, adhesion, abnormal consumption, increase of contact resistance and other fault phenomena while using.
(2)The material of power relay can be AgCd010,AgSn08,AgSnOlnO etc.Wanjia star brand relay adopted AgSnO2  with high quality & stable performance.  
(3)The mechanical service life and electrical service life can be main factor too
* In a word, good device need good relay to low the repairing rates and improve the endurance.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Registered Capital
1000000 RMB
Type of Ownership
Limited Company
Management System Certification
ISO 9001, ISO 14001, QC 080000