Application: | Electronic, Instrument, Position Sensor, Lighting, Submetering System |
---|---|
Type: | Current Transformer |
Phase: | Single |
Operation Condition: | Outdoor |
Usage: | Protection, Measurement, Monitoring |
Winding Form: | Small Fixed Type |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
This non-invasive current sensor (also known as a "split core current transformer") can be clamped around the supply line
of an electrical load to tell you how much current is passing through it. It does this by acting as an inductor and responding
to the magnetic field around a current-carrying conductor. By reading the amount of current being produced by the coil,
you can calculate how much current is passing through the conductor.
This particular current sensor will measure a load up to 30 Amps which makes it great for building your own energy monitor
to keep your power usage down, or even building an over-current protection device for an AC load. This sensor does not
have a load resistor built in, so in most cases it will be necessary to place a resistor across the output to convert the coil's
induced current to a very small measurable voltage.
Specification Data | Measuring Current Range | 100A |
Accuracy Class | Class 1 | |
Temperature Accuracy | 2ºC | |
Frequency | 50-60Hz | |
Wiring Diameter | ≤φ12mm | |
Operation Temperature | -20~+85ºC | |
Withstand Voltage | >3000VAC | |
Response Time | 200mS | |
Communication | M-BUS Communication |
Suppliers with verified business licenses