• Shunt Sampling 48VDC Battery Monitor DIN Rail Digital DC Power Energy Meter for Solar System
  • Shunt Sampling 48VDC Battery Monitor DIN Rail Digital DC Power Energy Meter for Solar System
  • Shunt Sampling 48VDC Battery Monitor DIN Rail Digital DC Power Energy Meter for Solar System
  • Shunt Sampling 48VDC Battery Monitor DIN Rail Digital DC Power Energy Meter for Solar System
  • Shunt Sampling 48VDC Battery Monitor DIN Rail Digital DC Power Energy Meter for Solar System

Shunt Sampling 48VDC Battery Monitor DIN Rail Digital DC Power Energy Meter for Solar System

Display: Digital
Installation: Direct Connected
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Maximum Demand Meter, Meter for Tender
Electric Equipment: Single-phase
Theory: Electronic Meter
Power Meter Connection: Terminal
Samples:
US$ 0.00/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Basic Info.

Model NO.
EM613001
Measured Signal
Pulse Peak
Type
Energy Meter
Certification
RoHS, ISO, CE, Kema
Customized
Customized
Product Name
LCD Display RS485 DIN Rail Digital DC Power Meter
Material
PC, ABS
Communication
RS485 Communication
Communication Protocol
Dtl645
Accuracy Class
Cl.1
LCD Display
LCD 6+2
Reference Voltage
DC40V-400V
Standard Compliant
GB/T 17708-2017 Static DC Energy Meter
Ref. Current
10~240A
Relative Humidity
95%
Transport Package
Bag Box Carton Pallet
Specification
150*36*80.5mm
Trademark
IVY
Origin
Zhejiang, China
HS Code
9028301300
Production Capacity
800, 000.00/ Month

Product Description

DC metering is used in specific applications to measure, collect, and store real-time data for DC power systems. It is widely used in various industries such as solar systems, EV charging stations, battery energy storage systems 

EM613001/EM613005 DC energy meters are designed for measuring and monitoring in DC systems.  They are an ideal solution for measuring and monitoring in DC systems. The din rail DC energy meters can measure of important DC parameters: Voltage, current, power and energy etc. It also support bi-directional measurement with pulse output. All data in the meter are accessible via RS 485 using Modbus RTU. The meter has two versions working with AC or DC power supply. Input voltage range up to 1000V DC, and current inputs are flexible with DC shunt. The multi-tariff version has a RTC equipped inside, it can provides multi-tariff information and monthly records.  

Shunt Sampling 48VDC Battery Monitor DIN Rail Digital DC Power Energy Meter for Solar SystemShunt Sampling 48VDC Battery Monitor DIN Rail Digital DC Power Energy Meter for Solar SystemShunt Sampling 48VDC Battery Monitor DIN Rail Digital DC Power Energy Meter for Solar SystemShunt Sampling 48VDC Battery Monitor DIN Rail Digital DC Power Energy Meter for Solar System
Specification Type Din Rail DC Measuring Device
Reference voltage DC40V-400V
Current 10~240A
Operation temp. -20ºC~+70ºC
Accuracy class Cl.1
Average humidity 75%
Relative humidity 95%
Communication RS485 Communication
Communication protocol DTL645
Impulse constant 100 imp/kWh
LCD display LCD 6+2
Power consumption ≤0.4W,≤8VA
Standard compliant GB/T 17708-2017 Static DC Energy Meter
Shunt Sampling 48VDC Battery Monitor DIN Rail Digital DC Power Energy Meter for Solar SystemShunt Sampling 48VDC Battery Monitor DIN Rail Digital DC Power Energy Meter for Solar SystemShunt Sampling 48VDC Battery Monitor DIN Rail Digital DC Power Energy Meter for Solar SystemShunt Sampling 48VDC Battery Monitor DIN Rail Digital DC Power Energy Meter for Solar SystemShunt Sampling 48VDC Battery Monitor DIN Rail Digital DC Power Energy Meter for Solar System
The Application of DC Energy Meter.
 
DC energy meters are used to measure the electrical energy consumed by a direct current (DC) load. They find applications in various industries such as renewable energy systems, telecommunications, data centers, electric vehicles, and battery storage systems.
 
In renewable energy systems, DC energy meters are used to monitor the power output of solar panels, wind turbines, and other renewable sources. In data centers and telecommunications, DC energy meters are used to measure the power consumption of servers and network equipment.
 
In electric vehicles, DC energy meters are used to measure the power consumed during charging and discharging of the vehicle's battery. They are also used to monitor the performance of the battery storage systems in various applications such as renewable energy systems, backup power systems, and off-grid power systems.
 
The Benefits/Advantages of DC Energy Meter.
 
DC energy meters offer several benefits and advantages, including:
 
Accurate measurement: DC energy meters provide accurate measurements of energy consumption, making it easier for users to monitor their energy usage and optimize their energy consumption.
 
Easy installation: DC energy meters are easy to install, making them an ideal solution for both residential and commercial applications.
 
Cost-effective: DC energy meters are generally cost-effective, and their accurate measurement of energy consumption can help users save money by reducing their energy usage.
 
Real-time monitoring: DC energy meters provide real-time monitoring of energy consumption, allowing users to track their energy usage and identify areas where they can reduce their energy consumption.
 
Data logging: DC energy meters can log energy consumption data, which can be used for analysis and reporting purposes.
 
Remote access: Many DC energy meters allow for remote access, enabling users to monitor their energy consumption from anywhere using a smartphone or computer.
 
Safety: DC energy meters are designed to be safe and reliable, ensuring that they do not pose a hazard to users or the environment.

Cautions of DC type Din Rail Meter:
 
1.About AC/DC & Application
(1) AC- Generally speaking alternating current usually means the input voltage , for example 220/230Vac for house 
appliance, 380Vac.
However DC for industrial field. In a word AC type energy meter is necessary when measuring in such condition.

(2) DC- Comparing with AC type meter, or AC whole current static energy meter, DC type Din Rail Meter was mainly used for direct current
measuring. It also means not for household and it;scarce.

(3) The application of DC din rail meter mainly exist where power storage for example power storage system, power generator, battery
system etc. It was also used for recharging such as EV charging pile.

 
2.About Function
(1) Measuring- current measuring achieved by shunt sampling which is cost-efficient and of good accuracy.
(2) Communication- RS485 Communication or RS485 & NB-IOT communication optional, which can also serve as DCU -sending data to the icloud.
(3) Tariff-4 tariffs with 8 slots.

3.Cautions
(1)Installation-Experienced electricians or professionals are required to install electricity meters and make sure that you have read this user guide.
In the process of installation, if the cover has obvious damage marks caused by severe impact or fall, please do not install or power up, and contact
with us immediately;Electricity meters can be installed and used directly if they pass the inspection before leaving the factory;The electricity meter
should be installed in the indoor or outdoor electricity meter box.The mounting base shall be fixed on a solid fire-resistant wall, and there shall be
no corrosive gas in the air;Electricity meters should be wired according to the wiring diagram on the terminal.Copper wire or copper wiring connector
are the best ways to access.
(2)Sealing- Plz fasten the sealing bolts or seals after installation in case of tamper events.
(3)If you have further questions while using plz contact us any time.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Registered Capital
1000000 RMB
Type of Ownership
Limited Company
Management System Certification
ISO 9001, ISO 14001, QC 080000