Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Theory: | Electromagnetic Relay |
| Usage: | Household Appliances Relay, Energy Meter, Industrial Control, EV Charger |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

| Parameter Category | Parameter | Value/Specification |
| General Parameters | Main Dimensions | 60 * 34.5 * 19 mm |
| Weight | 80g (excluding peripheral accessories) | |
| Operating Temperature | -40 to +85 °C | |
| Operating Humidity | 45% to 95% RH | |
| Contact Parameters | Contact Material | AgSnO2 |
| Contact Form | 2A or 2B (2 sets of Normally Open or Normally Closed) | |
| Contact Resistance | ≤ 0.8 mΩ (initial value, @DC 6~24V, 1A) | |
| Maximum Switching Current | 90A | |
| Maximum Switching Voltage | 250VAC | |
| Performance Parameters | Rated Coil Voltage | DC 6, 9, 12, 24V |
| Pulse Duration | 100ms ~ 200ms (recommended) | |
| Rated Coil Power | 2.5W (single coil), 5W (dual coil) | |
| Pick-up Time | ≤ 30ms | |
| Release Time | ≤ 30ms | |
| Electrical Life | 10,000 operations (purely resistive load, 90A 230VAC) | |
| Mechanical Life | 100,000 operations | |
| Insulation Resistance | 1000 MΩ (500VDC) | |
| Coil to Contacts | 4000VAC, 50/60Hz, 1 min | |
| Between Different Contact Groups | 4000VAC, 50/60Hz, 1 min | |
| Across Open Contacts of Same Group | 2000VAC, 50/60Hz, 1 min | |
| Short-Circuit Current Withstand | 4500A (50/60Hz), ~10ms (non-explosive) | |
| Shock Resistance (Functional) | 100 m/s² (10G) | |
| Shock Resistance (Destructive) | 1000 m/s² (100G) | |
| Vibration | 1.5mm (double amplitude), 10~55Hz |