5-1000V Modbus RS485 Dlt645 LCD6+2 DIN Rail DC Power Meter with Built-in Auxiliary Relays

Product Details
Customization: Available
Display: Digital
Installation: Direct Connected
Still deciding? Get samples of US$ 0.00/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
1000000 RMB
Type of Ownership
Limited Company
Management System Certification
ISO 9001, ISO 14001, QC 080000
  • 5-1000V Modbus RS485 Dlt645 LCD6+2 DIN Rail DC Power Meter with Built-in Auxiliary Relays
  • 5-1000V Modbus RS485 Dlt645 LCD6+2 DIN Rail DC Power Meter with Built-in Auxiliary Relays
  • 5-1000V Modbus RS485 Dlt645 LCD6+2 DIN Rail DC Power Meter with Built-in Auxiliary Relays
  • 5-1000V Modbus RS485 Dlt645 LCD6+2 DIN Rail DC Power Meter with Built-in Auxiliary Relays
  • 5-1000V Modbus RS485 Dlt645 LCD6+2 DIN Rail DC Power Meter with Built-in Auxiliary Relays
  • 5-1000V Modbus RS485 Dlt645 LCD6+2 DIN Rail DC Power Meter with Built-in Auxiliary Relays
Find Similar Products

Basic Info.

Model NO.
EM619002
Usage
Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Maximum Demand Meter
Electric Equipment
Single-phase
Theory
Electronic Meter
Power Meter Connection
Terminal
Measured Signal
Pulse Peak
Type
Energy Meter
Certification
RoHS, ISO, CE
Customized
Customized
Product Name
DC Solar Electric Meter
Ref. Current
Measuring Current up to 2000A
Reference Voltage
DC5V-1000V
Self-Powered Power Supply
DC9~60V
Communication
RS485 Communication
Communication Protocol
Dlt645/Modbus
Impulse Constant
1000 Imp/Kwh
Accuracy Class
Cl.1
LCD Display
LCD 6+2
Humidity
95%
Transport Package
Bag Box Carton Pallet
Specification
90*35.9*73mm
Trademark
IVY
Origin
Zhejiang, China
HS Code
9028301300
Production Capacity
800, 000.00/ Month

Product Description

5-1000V Modbus RS485 Dlt645 LCD6+2 DIN Rail DC Power Meter with Built-in Auxiliary Relays
1.EM619002 DC energy meters are designed for measuring and monitoring in DC systems.
2.The din rail DC energy meters can measure of important DC parameters: Voltage, current, power and energy etc. It also 
support bi-directional measurement. All data in the meter are accessible via RS485 using Modbus RTU/DTL645.
3.The meter working with DC power supply. Input voltage range up to 1000VDC, and current inputs are flexible with DC shunt.
4.The multi-tariff version has a RTC equipped inside, it can provides multi-tariff information and monthly records.

5.It can also be equipped with digital inputs for switch monitoring, relay outputs for remote control, and an over-range alarming
6.EM619001 dc meter is designed for scenarios such as DC panel, solar PV system, battery storage system, EV charging pile,
telecom base stations, transportation systems, power distribution systems, smart home and smart city.

5-1000V Modbus RS485 Dlt645 LCD6+2 DIN Rail DC Power Meter with Built-in Auxiliary Relays5-1000V Modbus RS485 Dlt645 LCD6+2 DIN Rail DC Power Meter with Built-in Auxiliary Relays5-1000V Modbus RS485 Dlt645 LCD6+2 DIN Rail DC Power Meter with Built-in Auxiliary Relays

      Specification EM619001 Din Rail DC Measuring Device
Reference voltage DC 5V-1000V
Current Shunt Connection Type, Max 2000A (Settable)
Max integration signal 75mV
Self-powered power supply 9~60VDC
Current / Voltage accuracy 0.5%
Operation temp. -25ºC~+70ºC
Active power accuracy 1.0%
Active accuracy class Cl.1.0
Humidity 95%
Communication RS485 Communication
Communication protocol DLT645/Modbus RTU
Impulse constant 1000 imp/kWh
LCD display LCD 6+2
Power consumption ≤0.4W,≤8VA
AC withstand voltage 4400V/min

5-1000V Modbus RS485 Dlt645 LCD6+2 DIN Rail DC Power Meter with Built-in Auxiliary Relays5-1000V Modbus RS485 Dlt645 LCD6+2 DIN Rail DC Power Meter with Built-in Auxiliary Relays5-1000V Modbus RS485 Dlt645 LCD6+2 DIN Rail DC Power Meter with Built-in Auxiliary Relays5-1000V Modbus RS485 Dlt645 LCD6+2 DIN Rail DC Power Meter with Built-in Auxiliary Relays5-1000V Modbus RS485 Dlt645 LCD6+2 DIN Rail DC Power Meter with Built-in Auxiliary Relays5-1000V Modbus RS485 Dlt645 LCD6+2 DIN Rail DC Power Meter with Built-in Auxiliary Relays5-1000V Modbus RS485 Dlt645 LCD6+2 DIN Rail DC Power Meter with Built-in Auxiliary Relays5-1000V Modbus RS485 Dlt645 LCD6+2 DIN Rail DC Power Meter with Built-in Auxiliary Relays
Cautions of DC type Din Rail Meter:

1.About AC/DC & Application
(1) AC- Generally speaking alternating current usually means the input voltage , for example 220/230Vac for house 
appliance, 380Vac.
However DC for industrial field. In a word AC type energy meter is necessary when measuring in such condition.

(2) DC- Comparing with AC type meter, or AC whole current static energy meter, DC type Din Rail Meter was mainly used for direct current
measuring. It also means not for household and it;scarce.

(3) The application of DC din rail meter mainly exist where power storage for example power storage system, power generator, battery
system etc. It was also used for recharging such as EV charging pile.

 
2.About Function
(1) Measuring- current measuring achieved by shunt sampling which is cost-efficient and of good accuracy.
(2) Communication- RS485 Communication or RS485 & NB-IOT communication optional, which can also serve as DCU -sending data to the icloud.
(3) Tariff-4 tariffs with 8 slots.

3.Cautions
(1)Installation-Experienced electricians or professionals are required to install electricity meters and make sure that you have read this user guide.
In the process of installation, if the cover has obvious damage marks caused by severe impact or fall, please do not install or power up, and contact
with us immediately;Electricity meters can be installed and used directly if they pass the inspection before leaving the factory;The electricity meter
should be installed in the indoor or outdoor electricity meter box.The mounting base shall be fixed on a solid fire-resistant wall, and there shall be
no corrosive gas in the air;Electricity meters should be wired according to the wiring diagram on the terminal.Copper wire or copper wiring connector
are the best ways to access.
(2)Sealing- Plz fasten the sealing bolts or seals after installation in case of tamper events.
(3)If you have further questions while using plz contact us any time.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier