80A Jqx 60f 12V 24V Refrigerator Overload UPS Relay Spst 1no 1nc

Product Details
Customization: Available
Theory: Electromagnetic Relay
Usage: Car Relay, Household Appliances Relay, Communication Relay, Lathe Relay, Stabilizer
Still deciding? Get samples of US$ 0.00/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
1000000 RMB
Type of Ownership
Limited Company
Management System Certification
ISO 9001, ISO 14001, QC 080000
  • 80A Jqx 60f 12V 24V Refrigerator Overload UPS Relay Spst 1no 1nc
  • 80A Jqx 60f 12V 24V Refrigerator Overload UPS Relay Spst 1no 1nc
  • 80A Jqx 60f 12V 24V Refrigerator Overload UPS Relay Spst 1no 1nc
  • 80A Jqx 60f 12V 24V Refrigerator Overload UPS Relay Spst 1no 1nc
  • 80A Jqx 60f 12V 24V Refrigerator Overload UPS Relay Spst 1no 1nc
Find Similar Products

Basic Info.

Model NO.
WJ177
Phase
1
Electricity Type
Ac
Number of Pole
1
Load
High Power Relay
Protective Characteristics
Sealed Relay
Action Principle
Electromagnetic Type
Size
Miniature
Type
Electric Parameter Relay
Product Name
High Power Industrial Relay 80A 12V 24VDC
Part Number
Wj177
Max Current
80A
Contact Arangement
1A,1b,1c/ No, Nc, Transfer
Contact Capacity
28VDC,250VAC
Coil Voltage
6~220VDC,6~240VAC
Color
Transparent
Contact Material
Agsno2
Weight
150.0
Mounting Method
Screw Fasten
Transport Package
100PCS in 1 Carton
Specification
76*42*46mm
Trademark
wanjia star
Origin
Zhejiang, China
HS Code
8536411000
Production Capacity
5, 000, 000.00/ Year

Product Description

Industrial Relay 80A Jqx 60f 12V 24VDC Refrigerator Overload Relay Spst 1no 1nc Power Relay with CE Mark

80A Jqx 60f 12V 24V Refrigerator Overload UPS Relay Spst 1no 1nc80A Jqx 60f 12V 24V Refrigerator Overload UPS Relay Spst 1no 1nc80A Jqx 60f 12V 24V Refrigerator Overload UPS Relay Spst 1no 1nc
Main Parameter
Contact Arrangement 1A,1B,1C
Contact Material Silver Alloy
Contact Resistance Max.50mΩ
Rated Load 80A 250VAC
80A 28VDC
Max. Switching Voltage 28VDC/250VAC
Max. Switching Current 80A
Max. Switching Power 2240W/20000VA
Electrical Life 1×104 
Mechanical Life 1×106
Coil Voltage 6~220VDC
Coil Power Consumption 3.0W
Other Parameters
Pick-up Time Max.30ms
Release Time Max.30ms
Starting Resistance Coil Contacts 2500VAC,(50/60Hz),1 min.
Open Contacts 1500VAC,(50/60Hz),1 min.
Insulation Resistance Min. 1000MΩ (500 VDC)
Environment Temperature -40ºC~+55ºC
Operation Humidity 45%~85% RH
Shock Resistance Functional Min. 10G
Destructive Min. 100G
Anti-vibration Functional 1.5mm(DA)10~55 Hz
Destructive 1.5mm(DA)10~55 Hz
Weight ≈200g
80A Jqx 60f 12V 24V Refrigerator Overload UPS Relay Spst 1no 1nc80A Jqx 60f 12V 24V Refrigerator Overload UPS Relay Spst 1no 1nc80A Jqx 60f 12V 24V Refrigerator Overload UPS Relay Spst 1no 1nc80A Jqx 60f 12V 24V Refrigerator Overload UPS Relay Spst 1no 1nc80A Jqx 60f 12V 24V Refrigerator Overload UPS Relay Spst 1no 1nc80A Jqx 60f 12V 24V Refrigerator Overload UPS Relay Spst 1no 1ncYou are here: Products>>Electric Relay>>220vac mini relay 

             Cautions of Power Relay:
 
               1.Suggestions of Plastic Anti-dust Cover
               We highly recommend cover :
               (1)When the ambient humidity is ≥ 60% (for example refrigerator or some country like Indian), the metal parts of relay will be weakened in different degrees
               due to long-term exposure to the outdoors in terms of electrical conductivity and service life.

               (2)When the dust density is high in the environment, all kinds of impurities carried in the dust (such as gravel), if gravel is embedded between contacts.
               Firstly, it will affect the normal opening and closing of contacts;Secondly, part of the silicon oxide can be used as a semiconductor to conduct electricity,
               and then the relay's on and off will fail if no anti-dust cover.

              (3)When corrosive gases are serious in the environment, it will accelerate the metal aging, greatly affecting the service life of electrical relays.
               * When none of the above situations exists, the plastic anti-dust cover is not necessary due to extra cost.
              2.Suggestions of Contacts
              (1)We should pay attention to prevent contact movement, adhesion, abnormal consumption, increase of contact resistance and other fault phenomena while using.
              (2)The material of power relay can be AgCd010,AgSn08,AgSnOlnO etc.Wanjia star brand relay adopted AgSnO2 with high quality & stable performance.  
              (3)The mechanical service life and electrical service life can be main factor too
              * In a word, good device need good relay to low the repairing rates and improve the endurance.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier