• 1 Phase 2 Wire MID Certificate RS485 Modbus Electrical Meter EV Charger Kwh Meter
  • 1 Phase 2 Wire MID Certificate RS485 Modbus Electrical Meter EV Charger Kwh Meter
  • 1 Phase 2 Wire MID Certificate RS485 Modbus Electrical Meter EV Charger Kwh Meter
  • 1 Phase 2 Wire MID Certificate RS485 Modbus Electrical Meter EV Charger Kwh Meter
  • 1 Phase 2 Wire MID Certificate RS485 Modbus Electrical Meter EV Charger Kwh Meter
  • 1 Phase 2 Wire MID Certificate RS485 Modbus Electrical Meter EV Charger Kwh Meter

1 Phase 2 Wire MID Certificate RS485 Modbus Electrical Meter EV Charger Kwh Meter

After-sales Service: 18 Mouth
Warranty: Free
Display: Indicator
Installation: Direct Connected
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter
Electric Equipment: Single-phase
Samples:
US$ 100/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Basic Info.

Model NO.
EM118089/90/91
Theory
Static Meter
Power Meter Connection
Terminal
Measured Signal
Pulse Peak
Type
Energy Meter
Certification
RoHS, ISO, CE, MID
Customized
Non-Customized
Accuracy Class
Class B
So Output
Yes
Tariff
Multi-Tariff
Certificate
MID/IEC
Transport Package
Carton, Pallet
Specification
TBA
Trademark
IVY METERING
Origin
Zhejiang, China
HS Code
9028301300
Production Capacity
8, 000, 000 PCS/Year

Product Description

Products Description
"EM118089/90/91" series meters are designed for DIN-Rail installation, suitable for grid-connected PV solar energy metering projects and EV charging metering solutions, the meters can measure and display various important power parameters, This products have RS485 communication interface, supporting Modbus which can meet the needs of data reading remotely of the monitoring system.. The meter has passed the approval of MID, EMC, and LVD. The bi-directional energy measurement makes the meter an excellent choice for solar metering.
 
(1)0.25(30A/32A/40A/45A/50/60/80/100A),
(2)Wide voltage range, 92V-230V, The lowest voltage can reach 40% of the standard voltage (EM118090)
(3)Active & Reactive, negative & positive Measurement
(4)RS485 Communication, SO Output
(5)Accuracy Class: Class B
(6)LCD Backlight, Multi-tariff, MID Approved, CE-EMC CE-LVD Compliant
(7)Bidirectional Metering
(8)Baud rate 9600/19200/38400/115200 can be set, default 9600bps
 
Type
EM118089
EM118090
EM118091
Ref. voltage
230V
Ref. current
0.25-5(30)A, 5(32)A,5(40)A,5(45)A, 5(50)A, 5(80)A, 5(100)A
Software Version
V101
V101
V101
CRC
5A8E
B6C9
6B8D
Impulse Constant
1000imp/kWh
1000imp/kWh
1000imp/kWh
Communication
N/A
RS485 Modbus/DLT645
RS485 Modbus/DLT645
Baud rate
N/A
9600\19200\38400\115200
9600\19200\38400\115200
SO output
Yes,SO1 for Active :
with variable constant
100-2500imp/kWh
Divisible by 10000
Yes,SO2 for Reactive:
with variable constant
100-2500imp/kvarh
Divisible by 10000
N/A
N/A
Li-Battery
N/A
N/A
YES
Multi-tariff
N/A
N/A
YES
Pulse width
SO:100-1000:100ms
SO:1000-2500:30ms
N/A
N/A
Backlight
Blue
Blue
Blue
Measurement Mode
1-Total =Forward
2-Total=Reverse
3-Total =Forward +Reverse (default)
4-Total=Forward-Reverse
1-Total =Forward
2-Total=Reverse
3-Total =Forward +Reverse (default)
4-Total=Forward-Reverse
1-Total =Forward
2-Total=Reverse
3-Total =Forward +Reverse (default)
4-Total=Forward-Reverse
Button
Touch button
Touch button
Touch button
Button function
Page turning, setting,
information display
Page turning, setting,
information display
Page turning, setting,
information display
Default setting
1000imp/kWh,100ms
1000imp/kvarh,100ms
9600/NONE /8/1
9600/NONE /8/1
Measurement
Mode setting
Button
RS485 or Button
RS485 or Button
1 Phase 2 Wire MID Certificate RS485 Modbus Electrical Meter EV Charger Kwh Meter
 
Application
1 Phase 2 Wire MID Certificate RS485 Modbus Electrical Meter EV Charger Kwh Meter
 

Company Exhibition
1 Phase 2 Wire MID Certificate RS485 Modbus Electrical Meter EV Charger Kwh Meter
Company Profile
1 Phase 2 Wire MID Certificate RS485 Modbus Electrical Meter EV Charger Kwh Meter
Cautions

 

1.About AC/DC Energy Meter
(1) AC or DC- Generally speaking alternating current or direct current shall be the first factor.
(2) We also have DC meter when you need to measure the Direct Current.

2.About Function
(1) As the content is limited, all functions mentioned above are the main functions
(2) Other functions such as TOU, load control, friendly hours,RTC, plz refer to the technical specification or
contact with our sales team.

3.About Application
(1) The applications only for examples, for the pratical situation the energy meter can also be used for
other applications.
(2) Welcome to inquiry if you are not sure about the functions or application, we have free technical support

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Registered Capital
1000000 RMB
Type of Ownership
Limited Company
Management System Certification
ISO 9001, ISO 14001, QC 080000