3-phase 120a IEC IEC62055-31 UC3 Compliant disconnection control latching relay for power meter
Basic parameters |
Dimension(mm) |
79*28*25.5mm |
Weight |
≈103g |
Ambient |
-45~+85ºC |
Contact parameters |
Contact Material |
AgSnO2 |
Contact Arrangement |
3A/3B |
Contact Resistance |
≤1.0mΩ |
Contact Load |
250VAC,120A |
Electrical Life |
32ΩMotor(Control voltage DC12~15V, rated resistive load) |
>=5000 cycles |
12ΩMotor(Control voltage DC12V, rated resistive load) |
10000 cycles |
Mechanical Life |
Control Voltage(DC12V Contact no load or micro current load) |
>=50000 cycles |
Performance parameters |
Rated Driving Voltage |
32ΩMotor |
12V(Advise pulse width 130-150ms) |
32ΩMotor |
15V(Advise pulse width 90-110ms) |
12ΩMotor |
10V(Advise pulse width 80-100ms) |
12ΩMotor |
12V(Advise pulse width 70-80ms) |
Motor Resistance(two styles optional) |
32(1±15%)Ω |
12(1±15%)Ω |
Vibration |
1.5mm(double amplitude),10~ 50Hz |
Shock |
1000m/s²,(100G) |
Surge Current |
6000A/10ms |
Insulation Resistance |
>1000MΩ(500VDC) |
Dielectric Strength |
Motor to Contact |
>4000VAC,1 min |
Across Open Contact |
>2000VAC,1 min |
Pole to Pole Contact |
>4000VAC, 1min |
Closing time at rated drive voltage |
32ΩMotor(12V) |
≤110ms |
32ΩMotor(15V) |
≤80ms |
12ΩMotor(10V) |
≤70ms |
12ΩMotor(12V) |
≤60ms |
Breaking time at rated driving voltage |
32ΩMotor(12V) |
≤80ms |
32ΩMotor(15V) |
≤50ms |
12ΩMotor(10V) |
≤50ms |
12ΩMotor(12V) |
≤40ms |
Cautions of Latching Relay:
1.Suggestions of relay's input
(1)Polarity-Please check the polarity inside of our technical specification, if single coil then"+ -" or "- +"are fine,
you can change it by one pulse.If double coil then it's necessary to confirm "-+-" or "+-+"before leaving the our factory.
(2)Driving-Please energize the relay at our recommend pulse width, rated voltage for reliable performance, if 1.5
times or 2 times of value or lower driving condition plz confirm with our engineer.
(3)Relays'contact status may be changed during transportation or installation due to impact of external force,
therefore please reset to the required status.
2.Suggestions of relay's output
(1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after
the installation.
(2)When the relay will be connected with screw or bolts to the relays' terminals, plz make sure your connection is
fastened and prevent relay from damages or other safety problems due to temp. Rise..
(3)The sampling signal wires of products are limited, please do not pull or torque during installation.